Swap power supplies, try different slots, power cycle the device, and reset the system.Confirm your device is powered on and connected to your computer. Note that some devices and modules are no longer supported in NI-DAQmx 17.6 and later. Confirm that you have DAQmx installed and determine the version of NI-DAQmx already installed on your system. Check to see if the correct drivers are installed for your DAQ hardware by checking the readme for that version of NI-DAQmx. You can find most NI-DAQmx readme’s on the NI-DAQmx Download Page. Ensure that you have the correct DAQmx driver software.If you are unable to locate it there, check through the NI Manuals. The DAQmx driver incompasses 3 parts, ADE Support, Device Driver, and MAX Configuration. ADE Support allows DAQmx to interface with LabVIEW. Term lab instacal drivers#ĭevice Driver has the drivers for the different DAQ devices. MAX Configuration allows you to configure the devices within NI MAX. You should see the following three under the Software drop-down in NI-MAX: You can check this in NI MAX by expanding My System » Software. Note: Your driver may not be version 18.1. InstaCal finds the DAQ device, but my application does not. If you do not have all three of these, please reinstall DAQmx. If you have recently installed new NI software, drivers, or hardware, restart your operating system (OS).If you recently installed to a newer version of LabVIEW, try repairing the DAQmx driver.You will then to need restart your system. With NI MAX open, start by refreshing the list of connected devices by clicking View»Refresh. Out-of-the-box virtual instrument suite with strip chart, oscilloscope, function generator, and rate generator professional version.Check to see whether your DAQ device appears in Windows Device Manager.If it does not, make sure that the device is plugged in correctly, and check for any loose connections. Also make sure that the PCI bus on your computer has the same Voltage rating as the DAQ card you are using. You can find the voltage ratings in the specification sheets for you computer and the DAQ card. If you are using an NI USB DAQ device, also review the section below. If your device or module does appear in Windows Device Manager, check under what category it appears.If your device appears under Data Acquisition Devices, verify the NI Device Loader service is started.If your device appears under a different category, complete one or both of the following procedures.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |